GP6059BK

AXELERON™ GP 6059 BK是陶氏(DOW)生产的一款优质的黑色LLDPE电缆护套化合物,具有优异的低温和高温性能、韧性、优异的环境应力开裂和耐候性以及挤出加工性能。制造商用于各种电信应用。也可用作高档电力电缆护套。

AXELERON™️  GP 6059 BK is a prime quality, black LLDPE cable jacket compound supplying superior low and high temperature performance, toughness, excellent environmental stress-crack and weather resistance, and extrusion processing. It can be used by wire and cable manufacturers for the entire range of telecommunication applications. Can also be used as a high-grade power cable jacket.

特点:卓越的耐候性,出色的机械性和灵活性,耐高温,紫外线稳定,抗应力开裂,出色的加工性。

Characteristics:Superior mechanical and electrical properties,Excellent dielectric properties

主要用途:光纤电缆,混合电缆,同轴电缆,射频电缆,网络和数据电缆,电力电缆。

Applications:Fiber optic cables、Hybrid cables、Coaxial cables、Radio frequency cables、Network and Data cables、Power cables

联系方式:17688193619    0769-87126376

获取报价:联系塑能

 

分类: 标签: ,

美国陶氏(DOW)

LLDPE AXELERON™ GP 6059 BK CPD

物性表(TECHNICAL  DATASHEET)

Technical Data Sheet
 

 

 

 

 

 

 

 

 

 

 

Overview   

AXELERON™ GP 6059 BK CPD Black Linear Low Density Polyethylene Compound for Cable Jacketing

AXELERON™ GP 6059 BK CPD Black Linear Low Density Polyethylene Compound for Cable Jacketing is a prime quality telephone cable black jacketing compound (“CPD”). It
offers improved low temperature and high temperature performance plus excellent environmental stress-cracking resistance, outdoor weatherability, and toughness.

Specifications

  • AXELERON™ GP 6059 BK CPD Black Linear Low Density Polyethylene Compound for
  • Cable Jacketing meets the following raw material specifications:
  • ASTM D 1248 IC-4, Grades E5, J1, J3
  • Federal LP-390C III-L, Grades 2, 3, 4 and Category 4
  • REA PE-22, 38, 39, 86, 89, 90 (Raw Materials Sections)
  • ISO 1872-PE, KCH, 18-D006
  • GB/T 15065

Cable jacketed with AXELERON™ GP 6059 BK CPD Black Linear Low Density Polyethylene Compound, using sound commercial extrusion practices, should meet the
following specifications:

  • ICEA: S-83-640
  • ASTM D 2308
  • Telcordia GR-421-CORE
  • EN 50290-2-24
  • IEC 60708
  • YD/T 901
  • IEC 60502 ST3, ST7
  • IEC 60840 ST3, ST7
  • HD 620 S2, Part 1, Table 4B, DMP 10, DMP 14, DMP 17
  • ICEA S-94-649
  • ICEA S-97-682
  • ICEA S-108-720
  • ICEA S-84-608
  • YD/T 1092
  • IEC 62067, ST3, ST7
  • IEC 60794
AXELERON™ GP 6059 BK CPD Properties
PhysicalNominal ValueUnit (English)Nominal ValueUnit (SI)Test Method1
Density0.932g/cm³0.932g/cm³ASTM D792
Melt Mass-Flow Rate (190°C/2.16 kg)0.60g/10 min0.60g/10 minASTM D1238
Environmental Stress-Cracking Resistance
(ESCR)2
10% Igepal, FO
> 1000hr> 1000hrASTM D1693
Carbon Black Content2.6%2.6%ASTM D1603
Absorption Coefficient> 400kAB/m> 400kAB/mASTM D3349
Mechanical
Tensile Strength
Break3,4
2350 psi 16.2 MPa ASTM D638
Break3050psi21.0MPaIEC 60811-501
Tensile Elongation
Break3,4
700%700%ASTM D638
Break900%900%IEC 60811-501
Thermal
Brittleness Temperature
F50
Notched, F50
< -148
< -105
°F
°F
< -100
< -76.0
°C
°C
ASTM D746
Oxidation Induction Time (392°F (200°C))120min120minASTM D3895
AXELERON™ GP 6059 BK CPD Electrical
Dielectric Constant (1 MHz)2.482.48ASTM D1531
Dissipation Factor (1 MHz)3.0E-43.0E-4ASTM D1531
Extrusion
Melt Temperature425 to 475°F218 to 246°C
Extrusion Notes
AXELERON™ GP 6059 BK CPD provides excellent surface finish and outstanding output rates over a broad range of conditions. For optimum results, use melt extrusion temperatures in the suggested range of 425 to 475°F (218 to 246°C).

Hopper drying at 150–160°F (67–71°C) is recommended to remove moisture.

 

 

 

AXELERON™ GP 6059 BK CPD

Product Stewardship

   1.      ASTM: American Society for Testing and Materials.
2.      Typical value per IEC 60811-406 > 1000 hrs.
3.      Type IV
4.      Speed 20 in/min (500 mm/min)

These are typical properties only and are not to be construed as specifications. Users should confirm results by their own tests.

The Dow Chemical Company and its subsidiaries (“Dow”) has a fundamental concern for all who make, distribute, and use its products, and for the environment in which we live. This concern is the basis for our Product Stewardship philosophy by which we assess the safety,
health, and environmental information on our products and then take appropriate steps to protect employee and public health and our environment. The success of our Product Stewardship program rests with each and every individual involved with Dow products -from
the initial concept and research, to manufacture, use, sale, disposal, and recycle of each product.

 

AXELERON™ GP 6059 BK CPD

Customer Notice

Dow strongly encourages its customers to review both their manufacturing processes and their applications of Dow products from the standpoint of human health and environmental quality to ensure that Dow products are not used in ways for which they are not intended or
tested. Dow personnel are available to answer your questions and to provide reasonable technical support. Dow product literature, including safety data sheets, should be consulted prior to use of Dow products. Current safety data sheets are available from Dow.
 

 

 

AXELERON™ GP 6059 BK CPD

Medical Applications Policy

NOTICE REGARDING MEDICAL APPLICATION RESTRICTIONS: Dow will not knowingly sell or sample any product or service (“Product”) into any commercial or developmental application that is intended for:

a.   long-term or permanent contact with internal bodily fluids or tissues. “Long-term” is contact which exceeds 72 continuous hours;

b.   use in cardiac prosthetic devices regardless of the length of time involved (“cardiac prosthetic devices” include, but are not limited to, pacemaker leads and devices, artificial hearts, heart valves, intra-aortic balloons and control systems, and ventricular bypass-assisted devices);

c.   use as a critical component in medical devices that support or sustain human life; or

d.   use specifically by pregnant women or in applications designed specifically to promote or interfere with human reproduction.

Dow requests that customers considering use of Dow products in medical applications notify Dow so that appropriate assessments may be conducted. Dow does not endorse or claim suitability of its products for specific medical applications. It is the responsibility of the
medical device or pharmaceutical manufacturer to determine that the Dow product is safe,lawful, and technically suitable for the intended use. DOW MAKES NO WARRANTIES,EXPRESS OR IMPLIED, CONCERNING THE SUITABILITY OF ANY DOW PRODUCT FOR USE IN MEDICAL APPLICATIONS.

Contact:

NOTICE: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, the Customer is responsible for determining whether products and the information in this document are appropriate for the Customer’s use and for ensuring that the Customer’s workplace and disposal practices are in compliance with applicable laws and other governmental enactments. Dow assumes no obligation or liability for the information in this document.

NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.

NOTICE: If products are described as “experimental” or “developmental”:

(1) product specifications may not be fully determined;

(2) analysis of hazards and caution in handling and use are required;

(3) there is greater potential for Dow to change specifications and/or discontinue production; and

(4) although Dow may from time to time provide samples of such products, Dow is not obligated to supply or otherwise commercialize such products for any use or application whatsoever.

NOTICE: This data is based on information Dow believes to be reliable, as demonstrated in controlled laboratory testing. They are offered in good faith, but without guarantee, as conditions and method of use of Dow products are beyond Dow’s control.Dow recommends that the prospective user determine the suitability of these materials and suggestions before adopting them on a commercial scale.

To the best of our knowledge, the information contained herein is accurate and reliable as of the date of publication, however we do not assume any liability for the accuracy and completeness of such information.

This document is intended for use within Africa & Middle East, Asia Pacific, Europe, Latin America, North America.

(免责声明:以上数据采集自网络,数据仅供参考,如有疑问,请联系厂家以厂家说明为准,版权归属于原作者,本页面仅供同行学习交流,如有侵权,请联系删除)

查看更多聚乙烯(PE)


Email:info@plaspowers.com 
www.plaspowers.com
sister corporation:Sunengtag
Wechat: sunengpv

wechat_orcode

评价

目前还没有评价

成为第一个“GP6059BK” 的评价者

您的邮箱地址不会被公开。 必填项已用 * 标注

您不能复制此页面的内容